Static electricity failure: Static electricity damage to the human body or equipment is a common cause of staticelectricity failure. To avoid this situation, anti-static measures need to be taken, such as adding grounding wires or metal mesh.
Gate breakdown: Excessive gate voltage can cause reverse breakdown between the gate and the substrate, resulting in gate breakdown failure. To avoid this situation, the gate voltage can be limited or a series current limiting resistor can be used to solve it.
Drain breakdown: Excessive drain voltage can cause reverse breakdown between the drain and the substrate, resulting in drain breakdown failure. To avoid this situation, methods such as limiting the drain voltage or series limiting resistors can be used.
Thermal runaway: An increase in temperature can lead to a decrease in channel resistance, forming a positive feedback loop, resulting in thermal runaway. To avoid this situation, methods such as increasing heat dissipation measures, reducing working current and power can be used.
In short, when designing and using electronic components, it is necessary to have an understanding and understanding of various failure causes and solutions to avoid damage or safety issues. If you need help, please feel free to contact us at any time